February 24, 2003 / 24 Février, 2003 1 Manual / Manuel 0-2929
Manual 0-2929
Remote Pendant Adapter Kit
Catalog # 7-3470
Installation Instructions
General Information
This kit connects a Thermal Dynamics Remote Pendant to SL60 or SL100 Torches equipped with the ATC connector.
Supplied Parts
The kit includes:
Adapter Fitting
Wire Assembly
•Wire Nut
Instructions
WARNING
Disconnect primary input power to the system before starting the installation.
Shut off input gas supply and bleed down the system.
Only a qualified technician should perform this procedure.
Installation Procedure
A. Preparation
1. Disconnect the ATC male connector from the female receptacle.
2. For shielded leads only:
a. Remove the tie wrap securing the outer woven nylon leads cover to the ATC connector.
b. Slide back the insulating boot covering the leads assembly and extending partway over the ATC connec-
tor.
c. Remove the metal tie wrap securing the wire mesh leads shield to the ATC Connector. Slide the wire
mesh leads shield off the ATC Connector.
3. Disassemble the ATC male connector as follows:
a. Remove 4 screws from the shell halves.
b. Separate and remove the shell halves.
4. One shell half includes a molded knockout. Remove the plastic material from this knockout. Smooth the
edges of the knockout.
© 2002 by Thermal Dynamics Corp., Printed in USA
82 Benning Street, West Lebanon, NH 03784 USA
(603) 298-5711 • www.thermal-dynamics.com
NOTE
The following sections differ between shielded and
unshielded applications.
Vista de página 0
1 2 3 4 5 6 ... 10 11

Resumo do Conteúdo

Página 1 - Installation Procedure

February 24, 2003 / 24 Février, 2003 1 Manual / Manuel 0-2929Manual 0-2929Remote Pendant Adapter KitCatalog # 7-3470Installation InstructionsGeneral I

Página 2 - ATC Male Connector, Rear View

February 24, 2003 / 24 Février, 2003 10 Manual / Manuel 0-2929D. Installation sur les Connecteurs Protégés d’ATC1. Référez-vous à l’illustration. Dévo

Página 3

February 24, 2003 / 24 Février, 2003 11 Manual / Manuel 0-2929Installation d’Adapteur, Fil ProtégéShield Wire to Connector Socket 8Douille IsolanteFil

Página 4

February 24, 2003 / 24 Février, 2003 2 Manual / Manuel 0-2929B. Installation on Unshielded ATC Connectors1. Refer to the illustration. Unfold Torch L

Página 5

February 24, 2003 / 24 Février, 2003 3 Manual / Manuel 0-2929A-03492Alignment KeyATC FemaleReceptacleATC MaleConnectorTo Power SupplyTo TorchLocking

Página 6

February 24, 2003 / 24 Février, 2003 4 Manual / Manuel 0-292956781234A-03501ATC Male Connector, Rear ViewD. Installation on Shielded ATC Connectors1.

Página 7 - Informations Générales

February 24, 2003 / 24 Février, 2003 5 Manual / Manuel 0-2929Shield WireShield Wire to Connector Socket 8ShieldInsulating BootLeadsPendant Adaper Wire

Página 8 - Protégés d’ATC

February 24, 2003 / 24 Février, 2003 6 Manual / Manuel 0-2929

Página 9 - A-03492F

February 24, 2003 / 24 Février, 2003 7 Manual / Manuel 0-292982 Benning Street, West Lebanon, NH 03784 USA(603) 298-5711 • www.thermal-dynamics.comM

Página 10

February 24, 2003 / 24 Février, 2003 8 Manual / Manuel 0-292956781234A-03501B. Installation sur les Connecteurs Non Protégés d’ATC1. Référez-vous à l’

Página 11 - A-03614F

February 24, 2003 / 24 Février, 2003 9 Manual / Manuel 0-2929Installation D’Adapteur, Fils Non protégésA-03492FÀ l'alimentation d'énergieAux

Comentários a estes Manuais

Sem comentários