Manual 0-4730 Rev. AF 8-15 TORCH DATA
Stainless Steel
100A
N
2
Plasma / H
2
0 Shield
Cartridge
21-1020
Electrode
21-1089
Plasma
Gas Distributor
21-1041
Tip
21-1053
Shield Cup
21-1016
Art # A-07214
Shield Cap
21-1036
Shield
Gas Distributor
21-1274
(in) inch (PSI) Ball (PSI) Ball (PSI) * Volts
(in)
±0.005
(ipm) (in) (sec) (in)
3/16 0.188 45 60 90 7 55 148 0.100 140 0.300 0.1 0.091
1/4 0.250 45 60 90 7 55 158 0.100 95 0.300 0.1 0.091
3/8 0.375 45 60 90 7 55 168 0.150 65 0.350 0.2 0.100
1/2 0.500 45 60 90 7 55 168 0.150 50 0.350 0.4 0.102
(Bar) Ball (Bar) Ball (Bar) * Volts
(mm)
±0.1
(mm/min) (mm) (sec) (mm)
3.1 60 6.2 7 3.8 149 2.5 3390 7.6 0.1 2.3
3.1 60 6.2 7 3.8 156 2.5 2665 7.6 0.1 2.3
3.1 60 6.2 7 3.8 163 3.8 2015 8.9 0.2 2.5
3.1 60 6.2 7 3.8 168 3.8 1595 8.9 0.3 2.6
3.1 60 6.2 7 3.8 168 3.8 1355 8.9 0.4 2.6
NOTE 2
: Water source used for H
2
O Water Shield must be demineralized.
100A Stainless Steel (N
2
/H
2
O)
Material
Thickness
Pre Flow
Pressure
(N
2
)
Cut Flow Rates / Pressures
Arc
Voltage
Torch
Working
Height
Travel
Speed
Initial
Piercing
Height
Pierce
Delay
Kerf
Width
@ Rec.
Speed
Plasma (N
2
) Shield (H
2
O)
Material
Thickness
Pre Flow
Pressure
(N
2
)
Cut Flow Rates / Pressures
Pierce
Delay
Kerf
Width
@ Rec.
Speed
Plasma (N
2
) Shield (H
2
O)
Arc
Voltage
Torch
Working
Height
Travel
Speed
Initial
Piercing
Height
(mm)
5
6
8
NOTE 1
: Ohmic height sensing is not recommended with water shield.
Water on the plate interferes electrically with the ohmic sensing circuit.
10
12
* Pressure of the water supply line should be regulated by customer supplied pressure regulator